Keyboard shortcuts

Press or to navigate between chapters

Press S or / to search in the book

Press ? to show this help

Press Esc to hide this help

⚙️ Technical Specifications

ParameterTechnical Data
Package dimensions8-Pin LGA with metal
3.0 x 3.0 x 0.93 mm³
Operation range (full accuracy)Pressure: 300...1100 hPa
Humidity: 0…100%
Temperature: -40…85°C
Supply voltage VDDIO1.2 - 3.6 V
Supply voltage VDD1.71 - 3.6 V
InterfaceI²C and SPI
Average current consumption2.1 µA at 1 Hz humidity and temperature
3.1 µA at 1 Hz pressure and temperature
3.7 µA at 1 Hz humidity, pressure and temperature
90 µA at ULP mode for p/h/T & air quality
0.9 mA at LP mode for p/h/T & air quality
3.9 mA in standard gas scan mode (gas scan mode & scan rate can be optimized on applications with BME AI studio)
Gas sensor - F1 score for H₂S scanning0.94
Gas sensor - Standard scan speed10.8 s / scan
Gas sensor - Electric charge for standard scan0.18 mAh (5 scans ~ 1 min)
Gas sensor - Response time (τ 33-63%)< 1 s (for new sensors)
Gas sensor - Sensor-to-sensor deviation+/- 15%
Gas sensor - Power consumption< 0.1 mA in ultra-low power mode
Gas sensor - Output data processingMajor direct outputs: Index for Air Quality (IAQ), bVOC-& CO₂-equivalents (ppm), Gas scan result (%) & many more (all listed in datasheet in Table 20: BSEC outputs)
Humidity sensor - Response time (τ0-63%)8 s
Humidity sensor - Accuracy tolerance± 3 % relative humidity
Humidity sensor - Hysteresis≤ 1.5 % relative humidity
Pressure sensor - RMS Noise0.12 Pa (equiv. to 1.7 cm)
Pressure sensor - Sensitivity Error± 0.25 % (equiv. to 1 m at 400 m height change)
Pressure sensor - Temperature coefficient offset±1.3 Pa/K (equiv. to ±10.9 cm at 1°C temperature change)